AMC011

Dataset contains 30min averages of many variables used to record changes in microclimatic conditions.

Download: 

AMC011.csv (57.18 MB)
Variables
DataCode
  • Label:
  • Definition: Data Set Code
  • Type: Nominal
  • Missing values: None specified
RecType
  • Label:
  • Definition: Record Type
  • Type: Nominal
  • Missing values: None specified
RecYear
  • Label:
  • Definition: The year of data collected
  • Type: Physical quantity
  • Unit: Year (YYYY)
  • Maximum: Not specified
  • Minimum: Not specified
  • Precision: Not specified
  • Missing values: None specified
Watershed
  • Label:
  • Definition: Watershed name, 4 watersheds: 1D, 1B, 4B, 4F
  • Type: Nominal
  • Missing values: None specified
location
  • Label:
  • Definition: location, Microclimate sensor stations were established in 10 locations
  • Type: Nominal
  • Missing values: None specified
doy
  • Label:
  • Definition: Day of year
  • Type: Physical quantity
  • Unit: number
  • Maximum: Not specified
  • Minimum: Not specified
  • Precision: Not specified
  • Missing values: None specified
hour_min
  • Label:
  • Definition: Time of day in 30 min intervals
  • Type: Physical quantity
  • Unit: minute
  • Maximum: Not specified
  • Minimum: Not specified
  • Precision: Not specified
  • Missing values: None specified
T_air
  • Label:
  • Definition: Air temperature (degC)
  • Type: Physical quantity
  • Unit: celsius
  • Maximum: Not specified
  • Minimum: Not specified
  • Precision: Not specified
  • Missing values:
    • -9999 = Missing or Not Measured
Tsoil_5cm
  • Label:
  • Definition: Soil temperature at 5cm depth (degC)
  • Type: Physical quantity
  • Unit: celsius
  • Maximum: Not specified
  • Minimum: Not specified
  • Precision: Not specified
  • Missing values:
    • -9999 = Missing or Not Measured
Tsoil_15cm
  • Label:
  • Definition: Soil temperature at 15cm depth (degC)
  • Type: Physical quantity
  • Unit: celsius
  • Maximum: Not specified
  • Minimum: Not specified
  • Precision: Not specified
  • Missing values:
    • -9999 = Missing or Not Measured
RH_mv
  • Label:
  • Definition: Relative humidity (mv)
  • Type: Physical quantity
  • Unit: percent
  • Maximum: Not specified
  • Minimum: Not specified
  • Precision: Not specified
  • Missing values:
    • -9999 = Missing or Not Measured
RH
  • Label:
  • Definition: Relative humidity (%)
  • Type: Physical quantity
  • Unit: percent
  • Maximum: Not specified
  • Minimum: Not specified
  • Precision: Not specified
  • Missing values:
    • -9999 = Missing or Not Measured
SBTemp
  • Label:
  • Definition: IRT sensor body temp (degC)
  • Type: Physical quantity
  • Unit: celsius
  • Maximum: Not specified
  • Minimum: Not specified
  • Precision: Not specified
  • Missing values:
    • -9999 = Missing or Not Measured
ws_ms
  • Label:
  • Definition: Wind speed (m/s)
  • Type: Physical quantity
  • Unit: metersPerSecond
  • Maximum: Not specified
  • Minimum: Not specified
  • Precision: Not specified
  • Missing values:
    • -9999 = Missing or Not Measured
SBTemp_c
  • Label:
  • Definition: IRT target temp (degC)
  • Type: Physical quantity
  • Unit: celsius
  • Maximum: Not specified
  • Minimum: Not specified
  • Precision: Not specified
  • Missing values:
    • -9999 = Missing or Not Measured
swc1_soilmoisture
  • Label:
  • Definition: 10cm depth soil moisture (wfv or m3-m-3)
  • Type: Physical quantity
  • Unit: number
  • Maximum: Not specified
  • Minimum: Not specified
  • Precision: Not specified
  • Missing values:
    • -9999 = Missing or Not Measured
swc1_conductivity_corrected
  • Label:
  • Definition: 10cm depth electrical conductivity (S / m)
  • Type: Physical quantity
  • Unit: siemensPerMeter
  • Maximum: Not specified
  • Minimum: Not specified
  • Precision: Not specified
  • Missing values:
    • -9999 = electrical conductivity
swc1_Temp_C
  • Label:
  • Definition: 10cm depth electrical conductivity (S / m)
  • Type: Physical quantity
  • Unit: celsius
  • Maximum: Not specified
  • Minimum: Not specified
  • Precision: Not specified
  • Missing values:
    • 1 = electrical conductivity
swc1_Temp_F
  • Label:
  • Definition: 10cm depth soil temperature (degF)
  • Type: Physical quantity
  • Unit: fahrenheit
  • Maximum: Not specified
  • Minimum: Not specified
  • Precision: Not specified
  • Missing values:
    • -9999 = Missing or Not Measured
swc1_real_dialectric_permittivity_corrected
  • Label:
  • Definition: 30cm dielectric permittivity (unitless)
  • Type: Physical quantity
  • Unit: number
  • Maximum: Not specified
  • Minimum: Not specified
  • Precision: Not specified
  • Missing values:
    • -9999 = Missing or Not Measured
swc2_soilmoisture
  • Label:
  • Definition: 30cm depth soil moisture (wfv or m3-m-3)
  • Type: Physical quantity
  • Unit: percent
  • Maximum: Not specified
  • Minimum: Not specified
  • Precision: Not specified
  • Missing values:
    • -9999 = Missing or Not Measured
swc2_conductivity_corrected
  • Label:
  • Definition: 30cm depth electrical conductivity (S / m)
  • Type: Physical quantity
  • Unit: siemensPerMeter
  • Maximum: Not specified
  • Minimum: Not specified
  • Precision: Not specified
  • Missing values:
    • -9999 = Missing or Not Measured
swc2_Temp_C
  • Label:
  • Definition: 30cm depth soil temperature (degC)
  • Type: Physical quantity
  • Unit: celsius
  • Maximum: Not specified
  • Minimum: Not specified
  • Precision: Not specified
  • Missing values:
    • -9999 = Missing or Not Measured
swc2_Temp_F
  • Label:
  • Definition: 30cm depth soil temperature (degF)
  • Type: Physical quantity
  • Unit: fahrenheit
  • Maximum: Not specified
  • Minimum: Not specified
  • Precision: Not specified
  • Missing values:
    • -9999 = Missing or Not Measured
swc2_real_dialectric_permittivity_corrected
  • Label:
  • Definition: 30cm dielectric permittivity (unitless)
  • Type: Physical quantity
  • Unit: number
  • Maximum: Not specified
  • Minimum: Not specified
  • Precision: Not specified
  • Missing values:
    • -9999 = Missing or Not Measured
swc3_soilmoisture
  • Label:
  • Definition: 100cm depth soil moisture (wfv or m3-m-3)
  • Type: Physical quantity
  • Unit: percent
  • Maximum: Not specified
  • Minimum: Not specified
  • Precision: Not specified
  • Missing values:
    • -9999 = Missing or Not Measured
swc3_conductivity_corrected
  • Label:
  • Definition: 100cm depth electrical conductivity (S / m)
  • Type: Physical quantity
  • Unit: siemensPerMeter
  • Maximum: Not specified
  • Minimum: Not specified
  • Precision: Not specified
  • Missing values:
    • -9999 = Missing or Not Measured
swc3_Temp_C
  • Label:
  • Definition: 100cm depth soil temperature (degC)
  • Type: Physical quantity
  • Unit: celsius
  • Maximum: Not specified
  • Minimum: Not specified
  • Precision: Not specified
  • Missing values:
    • -9999 = Missing or Not Measured
swc3_Temp_F
  • Label:
  • Definition: 100cm depth soil temperature (degF)
  • Type: Physical quantity
  • Unit: fahrenheit
  • Maximum: Not specified
  • Minimum: Not specified
  • Precision: Not specified
  • Missing values:
    • -9999 = Missing or Not Measured
swc3_real_dialectric_permittivity_corrected
  • Label:
  • Definition: 100cm dielectric permittivity (unitless)
  • Type: Physical quantity
  • Unit: number
  • Maximum: Not specified
  • Minimum: Not specified
  • Precision: Not specified
  • Missing values:
    • -9999 = Missing or Not Measured
Data Source Details

Header lines: 

1

Orientation: 

Column

Quote character: 

'

Field delimiter: 

,

Record delimiter: 

\r\n